By Mike SokolÂ
Dear Readers,
As promised, here’s Part 2 of my 12-volt DC short circuit tutorial. I’m splitting Part 2 into sub parts A and B, since there’s a LOT to learn about troubleshooting short circuits, and there’s only so much you can absorb in one sitting. So this is Part 2A. But if you haven’t read it already or just need a refresher, please review Part 1 from last week HERE.
Page Contents
Quick Review
First let’s take a quick review at what a short circuit looks like in a 12-volt DC circuit. You should remember from last week that the word “short” actually means a “shorter” circuit path than intended. And because the 12-volt bulb is what provided the current limiting in the non-shorted circuit, once you have a short in the wire you’ll blow a fuse every time you plug in a new one. That gets expensive and really doesn’t reveal anything diagnosticly.
First Steps
So what are we to do? Well, the simplest troubleshooting device we can add is an LED fuse which only cost about $1 each. While the fuse does indeed blow due to the huge short-circuit current available, now the LED light bulb is in the current path, and that tells us there’s at least 5 mA (5 milliamp or 0.005 amperes) of current flowing in the circuit.
Note that due to its low current requirements the LED bulb will light even if the short circuit has been removed but the bulb (or other load) is still in place. So if we want to find an intermittent short circuit with an LED fuse, the best way is to simply pop out the light bulb from the socket or removed any other load (as I’ve indicated in the diagram), then flex every wire and connector that’s in the circuit path and see if you can make the LED blink on and off. When the LED fuse is lit up you have a short circuit, and when the LED fuse is off there’s no short. So the trick is to flex, pound, twist and in general create mayhem with the wiring and see if the LED will flicker or go off.
Once you can create the intermittent short circuit at will, you simply divide and conquer the actions that will make it blink until you find the offending spot, which in many cases can be nothing more than a wire laying over a sharp metal edge that has cut through the insulation. If that’s the case, you can tape up the cut spot in the insulation and do something to keep it from being cut again. More on that in a future article.
But wait, there’s more…
However, what if you want to troubleshoot this problem while the main bulbs are still in the circuit. The fuse LED bulb draws so little current that it won’t know the difference between a short circuit and a normal circuit feeding a 12-volt light bulb load. So we have to increase the test current without creating so much fault current that it melts the wire.
Enter the 12-volt test light with a built-in incandescent bulb. You don’t want an LED version of this test light because it won’t draw the 1 amp or so of current you need for an in-load test. Note that in this example the test light will be drawing full current and be brightly lit, while the light bulb circuit in question has no current going through it and is off with no light at all.
Yes, even more…
The old-school version of the 12-volt tester is what you need since it draws more current than the modern LED models, and more current is what we need for testing like this. Note that instead of using this test light in the normal way between chassis ground and the hot terminal, you’re placing it in what used the fuse path. Now it’s doing two things. First, the bulb inside of the tester is limiting the fault current through the short circuit to 1 ampere or so and, second, it’s giving you a visual indication of how much current is flowing due to a short circuit.
Now, as you can see in the next graphic, depending on how much of a load you have downstream, the test light bulb may not be totally bright or dim without a short circuit since the load bulb is also limiting the current flow by its own resistance. But the test light will generally go from dim (with no short circuit) to fully bright (with a short circuit).
Now you can repeat the same wiggle process on the wiring while getting someone to watch the trouble light bulb for brightness changes. When the test light is fully bright and the load light is off, then the circuit is shorted. But when the test light is dim and the load light is dim, then there’s no longer a short circuit. The trick is to recognize what kind of twist, thump or wiggle causes the test light to change brightness. Then you’ve found where your short circuit is located.
One last thing…
Since this is a lot to absorb in one sitting, I’m going to give you a preview of what’s going to be included in Part 2B. Next week I’ll cover how to use a DC clamp ammeter to actually trace the fault current path in a complex short circuit. Note that most clamp meters only read AC current using their clamp jaws, so you’ll need one that’s rated for AC/DC current in the jaws themselves. We’ll not only use this cool tool for DC short circuit testing, we’ll also use it in Part 3, when we cover AC short circuit troubleshooting. See you then…
Let’s play safe out there….
Mike Sokol is an electrical and professional sound expert with 50+ years in the industry. His excellent book RV Electrical Safety is available at Amazon.com. For more info on Mike’s qualifications as an electrical expert, click here.
For information on how to support RVelectricity and No~Shock~Zone articles, seminars and videos, please click the I Like Mike Campaign.
##RVT931
My pannel box arcd and now only one two outlets work not the fridge what could it
I have a travel trailer
In the non-shorted test lamp diagram, isn’t there 1 amp flowing through the test lamp. Is it not completing the circuit and providing the 1/2 amp to the bulb? If so, this could be important at higher voltages and or amperes at the testing site.
In a complete series circuit, the current flow will be exactly the same everywhere in the circuit. So if there’s 1/2 amp current flowing through the bulb, then there will also be 1/2 amp flowing through the test light, and of course there’s only 1/2 amp through the switch. The reason why there’s only 1/2 amp of current with the test lamp instead of the 1 amp with the fuse, is that now there are two resistances in series, one being the load lamp and the other being the test light. So the amperage flow will reduce by at least 1/2 because the resistance was doubled. If you want to drill down into this more, read about Kirchhoff’s circuit laws here. https://en.wikipedia.org/wiki/Kirchhoff%27s_circuit_laws